Power system studies drawn to spec.
Independent arc flash, short circuit, load flow, protection coordination, harmonics, and stability studies — modelled, signed, and labelled by certified engineers.
Coupled studies. One model. One report.
IEEE 1584 / NFPA 70E arc flash incident energy modelling and PPE category labelling
Three-phase, line-to-ground, and asymmetric fault current per IEC 60909
Steady-state load flow with voltage drop and reactive compensation
Selectivity curves and TCC plots tuned for protection device coordination
Harmonic studies with IEEE 519 compliance checks
Transient stability and motor start analyses
Every panel, every breaker, every label.
Carelabs delivers integrated power-system studies as a single coupled model. Load flow, short circuit, arc flash, and protection coordination all share one validated network — eliminating the drift between standalone studies. Every report is signed by the lead engineer who walked the floor, never redrafted by an account manager. PPE labels are produced to your site's labelling standard and applied during the closeout visit.
Our studies use industry-standard software (ETAP, SKM, EasyPower) so your model is portable, your settings are exportable, and your insurers can audit the work in their tools of choice.
What lands in your inbox.
Signed engineering report
Methodology, assumptions, findings ranked by risk, and concrete mitigation paths.
Validated single-line diagram
As-built SLD with nameplate data, protective device settings, and cable schedule.
PPE labels
Site labels produced to IEEE 1584 / NFPA 70E thresholds, ready for application.
Native model file
ETAP / SKM / EasyPower source you keep — re-runnable for future changes.
Settings file for protective devices
Coordination-derived settings exported in the relay manufacturer's native format.
Closeout meeting
Engineer-led walkthrough of findings with your HSE, electrical, and operations teams.
How we ship a study.
Scope & Site Survey
On-site walk-down, single-line diagram review, nameplate verification, and protective device setting capture by a lead engineer.
Modelling & Analysis
Network rebuilt in industry-standard software. Coupled studies — load flow, short circuit, arc flash, protection coordination.
Findings & Mitigation
Every finding ranked by risk, with concrete mitigation paths — relay setting changes, breaker upgrades, PPE labelling.
Implementation & Verification
Re-issue after commissioning, retest, and sign-off. Closure on paper and on the floor — labelled, documented, signed.
Studies sign off to your auditors.
Common questions.
We scope per site after the initial walk-down. A fixed-fee proposal follows within the agreed quoting window with a named lead engineer and a deliverable list.
Yes. Deliverables align with NFPA 70E, IEEE 1584, IEC 60364, IEC 61482, ATEX, IECEx, BSI, and AS/NZS, and are issued by certified power systems engineers.
Most analytical work is offline from data we capture. Field testing is scheduled around your operations with planned outage windows or live techniques where safe and standards-compliant.
Ready to start the engagement?
Tell us about your project. We come back with a fixed scope, fixed fee, and a named lead engineer.